BCS-IDENT-MIB DEFINITIONS ::= BEGIN

IMPORTS

            DisplayString   FROM SNMPv2-TC
            OBJECT-TYPE     FROM SNMPv2-SMI
            MODULE-IDENTITY FROM SNMPv2-SMI;

gi      MODULE-IDENTITY
        LAST-UPDATED "201008250000Z"

        ORGANIZATION "Motorola Broadband Home Solutions"
        CONTACT-INFO "Motorola Technical Response Center
                      Inside USA     1-888-944-HELP (1-888-944-4357)
                      Outside USA    1-215-323-0044
                      TRC Hours:
                      Monday through Friday 8am - 7pm Eastern Standard Time
                      Saturdays            10am - 5pm Eastern Standard Time"

        DESCRIPTION  "The SMIv2 MIB module for the MOTOROLA BCS common ident objects.
                      The MIB Tree for this is shown below."

         ::= {iso org(3) dod(6) internet(1)  private(4) enterprises(1) 1166}

                
      giproducts    OBJECT IDENTIFIER      ::= { gi 1   } 
         acc4000d   OBJECT IDENTIFIER         ::= { giproducts 1    }
         anicd      OBJECT IDENTIFIER         ::= { giproducts 2    } 
         item1000   OBJECT IDENTIFIER         ::= { giproducts 4    }
         irt1000    OBJECT IDENTIFIER         ::= { giproducts 5    }
         nc1500     OBJECT IDENTIFIER         ::= { giproducts 6    }
-- OM-2000 shares same OID as OM-1000
         om1000     OBJECT IDENTIFIER         ::= { giproducts 7    } 
         im1000     OBJECT IDENTIFIER         ::= { giproducts 8    } 
         mps        OBJECT IDENTIFIER         ::= { giproducts 9    } 

         rpd1000    OBJECT IDENTIFIER         ::= { giproducts 10   }

-- Access Control Processors; TSODAs and other ACPs in various products.
         acpStatus  OBJECT IDENTIFIER         ::= { giproducts 11   } 
-- Heartbeat MIB used in the Satellite environment
         heartbeat  OBJECT IDENTIFIER         ::= { giproducts 12   }
-- Entitlement Key Common MIB - used by SDM/SEM
    entitlementKey  OBJECT IDENTIFIER         ::= { giproducts 13   }

         arpd       OBJECT IDENTIFIER         ::= { giproducts 14   }
         svom       OBJECT IDENTIFIER         ::= { giproducts 15   }
         svm        OBJECT IDENTIFIER         ::= { giproducts 16   }
         erm        OBJECT IDENTIFIER         ::= { giproducts 17   }
    
-- GI SURBboard BNH      
         surfBbnh   OBJECT IDENTIFIER         ::= { giproducts 18   } 

-- GI SURFboard cable modem
         sb2100     OBJECT IDENTIFIER         ::= { giproducts 19   } 
         sb2100D    OBJECT IDENTIFIER         ::= { giproducts 20   } 
         sb2000     OBJECT IDENTIFIER         ::= { giproducts 21   } 

-- CHS digital video headend equipment
--
         saDANIS    OBJECT IDENTIFIER         ::= { giproducts 30   } 
         apex       OBJECT IDENTIFIER         ::= { giproducts 31   } 
         rem        OBJECT IDENTIFIER         ::= { giproducts 32   } 
         mpe        OBJECT IDENTIFIER         ::= { giproducts 33   }
         spe        OBJECT IDENTIFIER         ::= { giproducts 34   }
         ne2000     OBJECT IDENTIFIER         ::= { giproducts 35   } 
         apex1500   OBJECT IDENTIFIER         ::= { giproducts 36   }
         agb        OBJECT IDENTIFIER         ::= { giproducts 37   }
         ne2500     OBJECT IDENTIFIER         ::= { giproducts 38   } 
--
         hdd2000    OBJECT IDENTIFIER         ::= { giproducts 40   } 
--
         merlin     OBJECT IDENTIFIER         ::= { giproducts 50   } 
--
         rsr        OBJECT IDENTIFIER         ::= { giproducts 60   } 
         gsrm       OBJECT IDENTIFIER         ::= { giproducts 61   } 
         gom        OBJECT IDENTIFIER         ::= { giproducts 62   }
         b3         OBJECT IDENTIFIER         ::= { giproducts 63   } 
         adm        OBJECT IDENTIFIER         ::= { giproducts 64   } 

-- San Diego Headend devices

         sem	    OBJECT IDENTIFIER	      ::= { giproducts 70   }
         ecmg       OBJECT IDENTIFIER         ::= { giproducts 71   } 
         bsiAdapter OBJECT IDENTIFIER         ::= { giproducts 72   }
         oles       OBJECT IDENTIFIER         ::= { giproducts 73   } 
         ne 	    OBJECT IDENTIFIER	      ::= { giproducts 74   }
         tmxCommTrap OBJECT IDENTIFIER        ::= { giproducts 75   }
         drmenginekskdc OBJECT IDENTIFIER     ::= { giproducts 76   }
         drmenginerte OBJECT IDENTIFIER       ::= { giproducts 77   }
         drmengineecmg OBJECT IDENTIFIER      ::= { giproducts 78   }
         drmengineskgpkg OBJECT IDENTIFIER    ::= { giproducts 79   }
         tmx	    OBJECT IDENTIFIER         ::= { giproducts 80   }
         prs        OBJECT IDENTIFIER         ::= { giproducts 81   }
         se2000     OBJECT IDENTIFIER         ::= { giproducts 82   }
         dem        OBJECT IDENTIFIER         ::= { giproducts 83   }
         ncs        OBJECT IDENTIFIER         ::= { giproducts 84   }
         ucs        OBJECT IDENTIFIER         ::= { giproducts 85   }
         lmm        OBJECT IDENTIFIER         ::= { giproducts 86   }
         se4000     OBJECT IDENTIFIER         ::= { giproducts 87   }
         rc         OBJECT IDENTIFIER         ::= { giproducts 88   }

--       
-- Element Management System Range
--
         netSentry  OBJECT IDENTIFIER         ::= { giproducts 99   }
         sdm	    OBJECT IDENTIFIER 	      ::= { giproducts 100  } 
         hfcEms     OBJECT IDENTIFIER         ::= { giproducts 101  }
         bnc        OBJECT IDENTIFIER         ::= { giproducts 102  }
         drmenginecm OBJECT IDENTIFIER        ::= { giproducts 103  }
         stdc	    OBJECT IDENTIFIER 	      ::= { giproducts 104  } 
         tview	    OBJECT IDENTIFIER 	      ::= { giproducts 105  } 
--
-- OIDS 106 thru 110 reserved for other EMS
--
--
--
-- OIDS 150 thru 225 reserved for TNS/NIS
--
         ponOa      OBJECT IDENTIFIER         ::= { giproducts 150   }
         mwtea200   OBJECT IDENTIFIER         ::= { giproducts 151   }

         bti        OBJECT IDENTIFIER         ::= { giproducts 200   }
         rfModMIB   OBJECT IDENTIFIER         ::= { giproducts 201   }
         btiIntMIB  OBJECT IDENTIFIER         ::= { giproducts 202   }
		 sg4000     OBJECT IDENTIFIER         ::= { giproducts 203   }

         ponEm870   OBJECT IDENTIFIER         ::= { giproducts 210   }
-- 
-- OIDS 250 thru 290 reserved for TAS
--
         rpa        OBJECT IDENTIFIER         ::= { giproducts 250   }
         rpc        OBJECT IDENTIFIER         ::= { giproducts 251   }
--
-- OIDS 300 thru 310 reserved for ASTBs
--       
         dct5000    OBJECT IDENTIFIER         ::= { giproducts 300   } 
         dct5100    OBJECT IDENTIFIER         ::= { giproducts 301   }
         dct5200    OBJECT IDENTIFIER         ::= { giproducts 302   }
--
-- OIDS 314 thru 320 reserved for other CPEs
--
         edfaMIB    OBJECT IDENTIFIER         ::= { giproducts 311   }
         corvusMIB  OBJECT IDENTIFIER         ::= { giproducts 312   }
         oa600      OBJECT IDENTIFIER         ::= { giproducts 313   }
--
-- Range 321-330 reserved for DSRs
--
         dsr350f    OBJECT IDENTIFIER         ::= { giproducts 321   }

         radd6000   OBJECT IDENTIFIER	      ::= { giproducts 400   } 
         cs1000     OBJECT IDENTIFIER         ::= { giproducts 401   }
         kls        OBJECT IDENTIFIER         ::= { giproducts 402   }
         dac6000    OBJECT IDENTIFIER         ::= { giproducts 403   }
         sdi	    OBJECT IDENTIFIER         ::= { giproducts 404   }
         cpms	    OBJECT IDENTIFIER         ::= { giproducts 405   }
         ap 	    OBJECT IDENTIFIER         ::= { giproducts 406   }
         ps		    OBJECT IDENTIFIER         ::= { giproducts 407   }
--
-- Range 350-359 reserved for Cable Cards
--
         cableCard  OBJECT IDENTIFIER         ::= { giproducts 350   }
--
-- The following branch identifies the BCS/IPNS Devices MIB.
--
      motoIPNSprodID OBJECT IDENTIFIER        ::= { giproducts 450 }
--
-- Range 500-510 reserved for Simulcrypt
--
--
-- Range 600-650 reserved for IRDs
--
      ird4500x      OBJECT IDENTIFIER         ::= { giproducts 610   }
      ird4520x      OBJECT IDENTIFIER	      ::= { giproducts 620   }

         
      giproxies     OBJECT IDENTIFIER         ::= { gi 3    } 

      gicommon      OBJECT IDENTIFIER         ::= { gi 4    } 
         identity   OBJECT IDENTIFIER         ::= { gicommon 1 }
         state      OBJECT IDENTIFIER         ::= { gicommon 2 }
         traps      OBJECT IDENTIFIER         ::= { gicommon 3 }
         logs       OBJECT IDENTIFIER         ::= { gicommon 4 }
--
--    nlsbbn		OBJECT IDENTIFIER         ::= { gi 5    }
-- 	added to create new path for gx2 hfc common and device mibs
      motproxies    OBJECT IDENTIFIER         ::= { gi 6    } 

--
-- The following is the SMIv2 COMMON MIB branch
--
      bcs           OBJECT IDENTIFIER         ::= { gi 7   } 
          bcsIdent  OBJECT IDENTIFIER      	  ::= { bcs 1 }
--        bcsState  OBJECT IDENTIFIER    	  ::= { bcs 2 }
--        bcsTraps  OBJECT IDENTIFIER     	  ::= { bcs 3 }
          bcsLogs   OBJECT IDENTIFIER     	  ::= { bcs 4 }

--        dms       OBJECT IDENTIFIER         ::= { bcs 5 }
--
-- New OID for SMIv2 of ACP MIB
--
--        bcs_acp   OBJECT IDENTIFIER         ::= { bcs 6 }
--
-- bcs OID 7 - 10  reserved for Simulcrypt
--
          bcsSimulcryptScs  OBJECT IDENTIFIER ::= { bcs 7 }
          bcsSimulcryptMux  OBJECT IDENTIFIER ::= { bcs 8 }
          bcsSimulcrypt     OBJECT IDENTIFIER ::= { bcs 9 }

-- bcs OID 11 - 20  reserved for common BCS infrastructure MIBs
--
          bcsDatabase       OBJECT IDENTIFIER ::= { bcs 11 }
          bcsRedundancy     OBJECT IDENTIFIER ::= { bcs 12 }

          bcsMsgGeneration  OBJECT IDENTIFIER ::= { bcs 21 }
--
--    Reserved for TNS
          mea       OBJECT IDENTIFIER         ::= { gi 8    }
--
-- Reserved for common Addressable Control MIBs
      addressablecontrol OBJECT IDENTIFIER      ::= { gi 9   } 
          acCommon     OBJECT IDENTIFIER      ::= { addressablecontrol 1 }
          acSecurity   OBJECT IDENTIFIER      ::= { addressablecontrol 2 }
          acServices   OBJECT IDENTIFIER      ::= { addressablecontrol 3 }
          acBsi        OBJECT IDENTIFIER      ::= { addressablecontrol 4 }
          acOperations OBJECT IDENTIFIER      ::= { addressablecontrol 5 }
          acTopology   OBJECT IDENTIFIER      ::= { addressablecontrol 6 }

--
-- Reserved for common CHS internal MIBs
      chsInternal      OBJECT IDENTIFIER      ::= { gi 10   } 
          emLogin      OBJECT IDENTIFIER      ::= { chsInternal 1 }
          radiusClient OBJECT IDENTIFIER      ::= { chsInternal 2 }
                     
-- Need to explicitly define EntryStatus since most do not recognize
-- the version 1 format.
EntryStatus ::= INTEGER
                         { valid(1),
                           createRequest(2),
                           underCreation(3),
                           invalid(4)
                         }
  
        -- groups in the GI-IDENT MIB

--  MIB Tree
--
--  The following diagram defining the objects in this MIB is for
--  reference purposes only.
--
--    bcs
--        |
--        +..bcsIdent
--        |    |
--        |    +..identSerialNumber
--        |    |
--        |    +..identChassisNumber
--        |    |
--        |    +..identIfIndex
--        |    |
--        |    +..identHardwareVersion
--        |    |
--        |    +..identHardwareFeatures
--        |    |
--        |    +..identInventoryCode
--        |    |
--        |    +..identSoftwareVersion
--        |    |
--        |    +..identLocationArea
--        |    |
--        |    +..identLocationRack
--        |    |
--        |    +..identLocationShelf
--        |    |
--        |    +..identMIBVersion
--        |    |
--        |    +..identAgentVersion
--        |    |
--        |    +..identCommand
--        |    |
--        |    +..identIfExtensionTable
--        |    |      |
--        |    |      +..identIfExtensionEntry
--        |    |           |
--        |    |           +..identIfExtensionIndex
--        |    |           |
--        |    |           +..identIfSerialNumber
--        |    |           |
--        |    |           +..identIfHardwareVersion
--        |    |           |
--        |    |           +..identIfHardwareFeatures
--        |    |           |
--        |    |           +..identIfInventoryCode
--        |    |           |
--        |    |           +..identIfFirmwareVersion1
--        |    |           |
--        |    |           +..identIfFirmwareVersion2
--        |    |           |
--        |    |           +..identIfFirmwareVersion3
--        |    |           |
--        |    |           +..identIfFirmwareVersion4
--        |    |           |
--        |    |           +..identIfSlotId
--        |    |           |
--        |    |           +..identIfCommand
--        |    |           |
--        |    |           +..identIfAdministrativeState
--        |    |           |
--        |    |           +..identIfOperationalState
--        |    |           |
--        |    |           +..identIfAlarmStatus
--        |    |           |
--        |    |           +..identIfAvailabilityStatus
--        |    |           |
--        |    |           +..identIfSpecific
--        |    |           |
--        |    |           +..identIfEntryStatus
--        |    |
--        |    +..identUnitModel         
         


-- The Identification Group.

-- This group of objects contains the identification of the software
-- and hardware for a specific unit.

    identSerialNumber OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains the serial number of the unit.  There is no 
             specification of the internal format of the serial number. 
             The serial number is entered into either permanent or non-
             volatile memory of the unit at the time of manufacture. 
             Note - the unit itself supplies the serial number."
        REFERENCE   " -- "
    ::= { bcsIdent 1 }

    identChassisNumber OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains the chassis number of the unit.  This is
             applicable only to a limited number of products, 
             currently, only the ITEM-1000.  For products for which
             this is not applicable, this will be a null object.
             There is no specification of the internal format of 
             the chassis number.  The means by which any product
             determines its chassis number is to be determined by
             each individual product."
        REFERENCE   " -- "
    ::= { bcsIdent 2 }


    identIfIndex OBJECT-TYPE
        SYNTAX      INTEGER (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains the IfIndex of the OAM&P port."
        REFERENCE   " -- " 
        DEFVAL { 2147483647 }
    ::= { bcsIdent 3 }


    identHardwareVersion OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the hardware
             version of this particular unit. There is no specification 
             of the internal format of the hardware version.  The 
             hardware version is entered into the either permanent or 
             non-volatile memory of the unit at the time of 
             manufacture."
        REFERENCE   " -- "
    ::= { bcsIdent 4 }


    identHardwareFeatures OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the features
             of this particular unit. There is no specification of the 
             internal format of the hardware features.  The hardware
             features is entered into the either permanent or 
             non-volatile memory of the unit at the time of 
             manufacture."
        REFERENCE   " -- "
    ::= { bcsIdent 5 }


    identInventoryCode OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the inventory 
             code for this unit.
             Once an inventory code has been set, it should be kept in 
             non-volatile memory.  The unit should only allow this object 
             to be set when it is in the 'configuration' mode.  There is 
             no specification of the internal format of  the inventory 
             Code."
        REFERENCE   " -- "
    ::= { bcsIdent 6 }


    identSoftwareVersion OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the current 
             version of the software for this unit.  The format of the 
             software version is a fully qualified directory name.  This 
             value is received by a unit as within a BOOTP response from 
             the BOOTP server.  It is available to the network manager 
             for applications that track the installed software.  Once 
             the software  version has been set, it should be kept in 
             non-volatile memory."
        REFERENCE   " -- "
    ::= { bcsIdent 7 }


    identLocationArea OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This is different from the MIB II sysLocation variable as it
            contains only the location area and does not describe the
            precise location.
            This contains a display string that defines the area in 
             which the unit is installed.  Location is defined by a set 
             of three objects: 'Area', 'Rack', and 'Shelf'.    These 
             location objects cannot be determined by the unit itself, 
             but can only be determined by the network manager.  It is 
             available to the unit for display on a front panel.  Display 
             of the location on the front panel is useful in validating 
             the configuration established by the network manager.  The 
             unit should only allow this object to be set when it is in 
             the 'configuration' mode.  Once the Location Area has been 
             set, it should be kept in non-volatile memory."
        REFERENCE   " -- "
    ::= { bcsIdent 8 }


    identLocationRack OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the rack in
             which the unit is installed.  Location is defined by a set
             of three objects: 'Area', 'Rack', and 'Shelf'.    These 
             location objects cannot be determined by the unit itself,
             but can only be determined by the network manager.  It is
             available to the unit for display on a front panel.  Display
             of the location on the front panel is useful in validating
             the configuration established by the network manager.  The
             unit should only allow this object to be set when it is in
             the 'configuration' mode.  Once the Location Area has been
             set, it should be kept in non-volatile memory."
        REFERENCE   " -- "
    ::= { bcsIdent 9 }


    identLocationShelf OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the shelf in 
             which the unit is installed.  Location is defined by a set 
             of three objects: 'Area', 'Rack', and 'Shelf'.    These 
             location objects cannot be determined by the unit itself, 
             but can only be determined by the network manager.  It is 
             available to the unit for display on a front panel.  Display 
             of the location on the front panel is useful in validating 
             the configuration established by the network manager.  The 
             unit should only allow this object to be set when it is in 
             the 'configuration' mode.  Once the Location Area has been 
             set, it should be kept in non-volatile memory."
        REFERENCE   " -- "
    ::= { bcsIdent 10 }



    identMIBVersion OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            " The version number of this MIB."
        REFERENCE   " -- "
    ::= { bcsIdent 11 }


    identAgentVersion OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "The version number of the Agent."
        REFERENCE   " -- "
    ::= { bcsIdent 12 }


    identCommand OBJECT-TYPE
        SYNTAX      INTEGER
            {
              restart(1),
              currentlyRestarting(2),
              unspecified(3),
	          purgeAndRestart(4),
	          currentlyPurgingAndRestarting(5),
	          purgeNvramAndRestart(6),
              currentlyPurgingNvramAndRestarting(7)
            }
                      
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This is the command to be executed by the resource
            managed by the agent.
            The value unspecified is always returned on SNMP
            Get/GetNext while the resource is running. If the
            restart(1) command is given, currentlyRestarting(2)
            is returned while the resource is preparing to
            restart (reboot)."
        REFERENCE   " -- "
    ::= { bcsIdent 13 }


    identIfExtensionTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF IdentIfExtensionEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION 
        "This table contains extensions to the MIB II ifTable which  contains
            the definitions of all interfaces. An ifTable entry may be a board
            or just a port on a board. Any ifTable entry can have an extension
            in the identIfExtensionTable. The corrsponding entry in that table
            will have the identIfIndex = ifIndex. Within the ifTable the presence
            of such an entry is indicated by setting the variable ifSpecific
            to the OBJECT IDENTIFIER value of identIfExtensionTable. Otherwise
            iFSpecific is set to {0 0}.
            The ifType - other - is used for all board types not envisoned by
            MIB II."
        REFERENCE   " -- "
    ::= { bcsIdent 14 }


    identIfExtensionEntry OBJECT-TYPE
        SYNTAX      IdentIfExtensionEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION 
            "An entry (conceptual row) in the Board Table."
        REFERENCE   " -- "
       INDEX           { identIfExtensionIndex }
    ::= { identIfExtensionTable 1 }



    IdentIfExtensionEntry ::= SEQUENCE 
    {
        identIfExtensionIndex       INTEGER,
        identIfSerialNumber         DisplayString,
        identIfHardwareVersion      DisplayString,
        identIfHardwareFeatures     DisplayString,
        identIfInventoryCode        DisplayString,
        identIfFirmwareVersion1     DisplayString,
        identIfFirmwareVersion2     DisplayString,
        identIfFirmwareVersion3     DisplayString,
        identIfFirmwareVersion4     DisplayString,
        identIfSlotId               INTEGER,
        identIfCommand              INTEGER,
        identIfAdministrativeState  INTEGER,
        identIfOperationalState     INTEGER,
        identIfAlarmStatus          INTEGER,
        identIfAvailabilityStatus   INTEGER,
        identIfSpecific             OBJECT IDENTIFIER,
        identIfEntryStatus          EntryStatus
    }


    identIfExtensionIndex OBJECT-TYPE
        SYNTAX      INTEGER  (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "Same value as ifIndex of MIB II for the same board."
        REFERENCE   " -- " 
        DEFVAL { 2147483647 }
    ::= { identIfExtensionEntry 1 }


    identIfSerialNumber OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains the serial number of the board.  There is no 
             specification of the internal format of the serial number.  
             The serial number is entered into either permanent or 
             non-volatile memory of the unit at the time of manufacture.  
             Note - the unit itself supplies the serial number."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 2 }



    identIfHardwareVersion OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the version
             of this particular board. There is no specification of the 
             internal format of the hardware version.  The hardware
             version is entered into the either permanent or 
             non-volatile memory of the unit at the time of 
             manufacture."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 3 }


    identIfHardwareFeatures OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the features of 
             this particular board. There is no specification of the 
             internal format of the hardware features.  The hardware 
             features is entered into the either permanent or 
             non-volatile memory of the unit at the time of manufacture."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 4 }


    identIfInventoryCode OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This contains a display string that defines the inventory 
             code for this board.  This is an optional value; if there is 
             no inventory code, The unit will respond with a null string.  
             Once an inventory code has been set, it should be kept in 
             non-volatile memory.  The unit should only allow this object 
             to be set when it is in the 'configuration' mode.  There is 
             no specification of the internal format of the inventory 
             Code."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 5 }



    identIfFirmwareVersion1 OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "Within a product, there may be several identifiers of such 
             firmware, boot proms, kernel versions, flash versions, etc.  
             This field (and the 3 that follow) are used to hold the 
             identification of these items.  These values must be entered 
             into the board at the time of manufacturing.  Unused fields 
             are reported as null values. These fields are available to 
             the network manager for applications that keep track of the
             firmware related identification.  There is no specification 
             of the internal format of firmware version identifiers."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 6 }


    identIfFirmwareVersion2 OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "Firmware related identification field # 2."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 7 }


    identIfFirmwareVersion3 OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "Firmware related identification field # 3."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 8 }


    identIfFirmwareVersion4 OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "Firmware related identification field # 4"
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 9 }


    identIfSlotId OBJECT-TYPE
        SYNTAX      INTEGER  (1..2147483647)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This variable identifies the board slot."
        REFERENCE   " -- "
        DEFVAL { 2147483647 }
    ::= { identIfExtensionEntry 10 }


    identIfCommand OBJECT-TYPE
        SYNTAX      INTEGER
            {
             unspecified(1),
             reset(2),
             restart(3),
             halt(4)
            }
             
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "This is the command to be executed by the resource
            managed by the agent.
            The value unspecified(10 is always returned on SNMP
            Get/GetNext while the other values are set by the manager
            and executed by the resource."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 11 }


    identIfAdministrativeState  OBJECT-TYPE
        SYNTAX      INTEGER
          {
             locked(1),
             unlocked(2),
             shuttingDown(3)
          }

        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            " The current Adminsitrative state of the interface as defined in
                          ISO/IEC 10164-2."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 12 }


    identIfOperationalState  OBJECT-TYPE
        SYNTAX      INTEGER
          {
             enabled(1),
             disabled(2)
          }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "       The current Operational state of the interface as defined in
                          ISO/IEC 10164-2"
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 13 }


    identIfAlarmStatus    OBJECT-TYPE
        SYNTAX      INTEGER
          {
              underRepair(1),
              critical(2),
              major(3),
              minor(4),
              alarmOutstanding(5),
              idle(6)
          }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION 
            "       This object defines the Alarm status of the interface
                   as defined in ISO/IEC 10164-2 and state-machine"
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 14 }        


    identIfAvailabilityStatus    OBJECT-TYPE
        SYNTAX      INTEGER
            {
               inTest(1),
               failed(2),
               powerOff(3),
               offLine(4),
               offDuty(5),
               dependency(6),
               degraded(7),
               notInstalled(8),
               logFull(9),
               available(10)
            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
             "       This object controls the Availability status of the interface
              as defined in ISO/IEC 10164-2 and state-machine"
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 15 }        


    identIfSpecific OBJECT-TYPE
        SYNTAX      OBJECT IDENTIFIER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            " The object identifier of a board type specific
             extension to the ifTable if necessary. Otherwise,
             identIfSpecific is set to {0 0}."
        REFERENCE   " -- "
    ::= { identIfExtensionEntry 16 }


   identIfEntryStatus OBJECT-TYPE
       SYNTAX     EntryStatus
        MAX-ACCESS read-write
        STATUS     current
        DESCRIPTION
        "This object is used to create, delete or
         modify a row in this table.  To create a
         a new network element, this object is initially
         set to 'createRequest'.  After completion of the
         configuration of the new entry, the  manager
         must set the appropriate instance of this object
         to the value valid(1) or aborts, setting this object
         to invalid(4).  This object must not be set to
         'active' unless the following columnar objects
         exist in this row:
               identIfExtensionIndex
               identIfSerialNumber
               identIfHardwareVersion
               identIfInventoryCode
               identIfFirmwareVersion1
              identIfSpecific
         To delete an existing entry in this table,
         the manager must set the appropriate
         instance of this object to the value invalid(4).
         Creation of an instance of this object has the
         effect of creating the supplemental object instances
         to complete the conceptual row.  An existing instance
         of this entry cannot be created.  If circumstances 
         occur which cause an entry to become invalid, the 
         agent modifies the value of the appropriate instance 
         of this object to invalid(4).  Whenever, the value of 
         this object for a particular entry becomes 
         invalid(4), the conceptual row for that instance may 
         be removed from the table at any time, either
         immediately or subsequently."
         DEFVAL { valid }
    ::= { identIfExtensionEntry 17 }



    identUnitModel OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This contains the model of the product.  For example,
             the ITEM-1000 would contain 'ITEM1000'. "
        REFERENCE   " -- "
    ::= { bcsIdent 15 }




END